BTEX and Naphthalene Bioremediation to BDL by Petrox Microbes

Case Study:
Orange County Fire and Rescue Station 81, Orlando, Florida

Oculus Number 8520434

Petrox was used to treat the residual petroleum contamination in ground water after the leaking tank was removed.  The petroleum contamination exceeded applicable standards for benzene, toluene, ethylbenzene, and xylene (BTEX) and naphthalene.  Petrox was injected into the ground water through 28 injection points covering a plume area of approximately 6,300 square feet.   Petrox injections were completed on June 18, September 11, and November 1, 2002.

Prior to bioaugmentation 100 pounds of ORC was added to provide supplemental oxygen for the bioremediation.  After verifying the dissolved oxygen concentration was more than 1.0 mg/l, the site was ready for bioaugmentation.

During the first injection 10 drums of Petrox were injected to cover the full plume.  As the area of contamination decreased, less Petrox was injected.  Five drums were injected in a focused application on September 11 and November 1, 2002.

Quarterly monitoring was completed during and after the inoculation to determine the bioremediation results.  The cleanup goals were achieved in the source area after the first inoculation.  The contamination persisted, however, in the down gradient wells.  The cleanup goals were achieved in the down gradient monitoring well after the third injection, but there was subsequent rebound.  After full distribution of Petrox was reached throughout the plume, the BTEX and naphthalene concentration were below detection limits (BDL), and cleanup goals were achieved and maintained. 

Please refer to the table below for the ground water monitoring results.

Monitoring Well Date Benzene Toluene Ethylbenzene Total Xylenes Naphthalene
MW-7 Source Area 6/12/2000 5.0 46.0 18.0 90.0 24.0
6/13/2001 39.0 272.0 167.0 526.0 26.0
3/14/2002 21.0 19.0 102.0 266.0 39.0
6/5/2002 ORC Added
6/18/02 10 Drums of Petrox Added
7/14/2002 <1.0 <1.0 <1.0 <2.0 <1.0
9/11/2002 <1.0 <1.0 <1.0 <2.0 <1.0
9/11/02 5 Drums of Petrox Added
10/7/2002 <1.0 <1.0 <1.0 <2.0 <1.0
11/1/02 5 Drums of Petrox Added
12/2/2002 <1.0 <1.0 <1.0 <2.0 <1.0
1/9/2003 <1.0 <1.0 <1.0 <3.0 <5.0
4/17/2003 <1.0 <1.0 <1.0 <2.0 <1.0
             
MW-8

Down Gradient

6/12/2000 2.0 72.0 21.0 109.0 39.0
6/13/2001 14.8 677.0 207.0 1292.0 113.0
3/14/2002 71.0 1198.0 357.0 2408.0 193.0
6/5/2002 ORC Added
6/18/02 10 Drums of Petrox Added
7/15/2002 19.0 515.0 170.0 690.0 39.0
9/11/2002 <1.0 3.7 3.8 16.4 <1.0
9/11/02 5 Drums of Petrox Added
10/7/2002 6.4 2.3 4.7 23.8 15.0
11/1/02 5 Drums of Petrox Added
12/2/2002 38.0 515.0 95.0 460.0 10.0
1/9/2003 <1.0 <1.0 <1.0 <3.0 <5.0
4/17/2003 <110.0 1060.0 285.0 1120.0 65.0
4/29/2004 <1.0 <1.0 <1.0 <1.0 <1.0
9/1/2004 <1.0 <1.0 <1.0 <1.0 <1.0
12/1/2004 <1.0 <1.0 <1.0 <1.0 <1.0
3/21/2004 <1.0 <1.0 <1.0 <1.0 <1.0